Colomb. med ; 48(3): 120-125, July-Sept. 2017. tab, graf
Artigo em Inglês | LILACS | ID: biblio-890866

RESUMO

Abstract Introduction: The environment of neonatal intensive care units is influenced by numerous sources of noise emission, which contribute to raise the noise levels, and may cause hearing impairment and other physiological and psychological changes on the newborn, as well as problems with care staff. Objective: To evaluate the level and sources of noise in the neonatal intensive care unit. Methods: Sampled for 20 consecutive days every 60 seconds in A-weighting curves and fast mode with a Type I sound level meter. Recorded the average, maximum and minimum, and the 10th, 50th and 90th percentiles. The values are integrated into hours and work shift, and studied by analysis of variance. The sources were characterized in thirds of octaves. Results: The average level was 64.00 ±3.62 dB(A), with maximum of 76.04 ±5.73 dB(A), minimum of 54.84 ±2.61dB(A), and background noise of 57.95 ±2.83 dB(A). We found four sources with levels between 16.8-63.3 dB(A). Statistical analysis showed significant differences between the hours and work shift, with higher values in the early hours of the day. Conclusion: The values presented exceed the standards suggested by several organizations. The sources identified and measured recorded high values in low frequencies.


Resumen Introducción: El ambiente de las unidades de cuidado intensivo neonatal está influenciado por numerosas fuentes de emisión de ruido, que contribuyen a elevar los niveles de ruido y que pueden provocar deficiencias auditivas entre otras alteraciones fisiológicas y psicológicas sobre el neonato, así como problemas al personal asistencial cuando se exceden los niveles. Objetivo: Evaluar el nivel y fuentes de emisión del ruido en la unidad de cuidado intensivo neonatal. Métodos: Se muestreo durante 20 días continuos cada 60 segundos en escala de ponderación frecuencias A y espacial fast, con un sonómetro tipo I, se registraron los parámetros acústicos de nivel medio, máximo y mínimo, y percentil 10, 50 y 90. Se integraron en periodos horarios y por turno, y se estudiaron mediante un análisis de varianza. Las fuentes se caracterizaron en tercios de octavas. Resultados: El nivel medio reportado fue 64.00 ±3.62 dB(A), con máximo de 76.04 ±5.73 dB(A), mínimo de 54.84 ±2.61 dB(A) y ruido de fondo de 57.95 ±2.83 dB(A). Se identificaron cuatro fuentes con rango entre 16.8-63.3 dB(A). El análisis estadístico mostró diferencias significativas entre una media y otra con valores mayores en las primeras horas del día. Conclusión: Los valores presentados superan los estándares sugerido por diversas organizaciones. Las fuentes identificadas y medidas registraron mayor aporte en las frecuencias bajas.


Assuntos
Humanos , Recém-Nascido , Unidades de Terapia Intensiva Neonatal , Ruído , Fatores de Tempo , Unidades de Terapia Intensiva Neonatal/normas , Análise de Variância , Colômbia , Hospitais Públicos , Hospitais de Ensino , Ruído Ocupacional
2.
Univ. salud ; 17(2): 163-169, jul.-dic. 2015. ilus, tab
Artigo em Espanhol | LILACS | ID: lil-774977

RESUMO

Objetivo: Evaluar el nivel continuo equivalente de ruido en una unidad de cuidado intensivo adulto perteneciente a un hospital de la ciudad de Santa Marta con los niveles sugeridos por los estándares internacionales. Materiales y métodos: Se realizó un muestreo continuo durante 20 días registrando datos cada minuto con un sonómetro tipo I en un eje central de la unidad de cuidado intensivo adulto del hospital; los datos registrados correspondían a los valores máximos, mínimos y el nivel continuo equivalente de ruido en ponderación frecuencial A y el filtro de ponderación temporal Fast. Resultados: Se reporta que el nivel de ruido continuo equivalente varió entre 49 ­ 71 dBA con un valor máximo de 91,19 dBA y un mínimo de 46,65 dBA. El análisis de varianza infiere que el valor medio de ruido varía con la hora del día. Conclusiones: El nivel de ruido continuo equivalente presentado en la unidad de cuidado intensivo adulto es consistente con otros estudios similares, no obstante los valores presentados exceden los estándares internacionales de ruido sugeridos, generando una preocupación por los riesgos de exposición a los que se encuentran pacientes y personal médico de la unidad.


Objective: To assess the continuous equivalent noise level in an intensive care unit for adults that belongs to a hospital in the city of Santa Marta using the levels suggested by international standards. Materials and methods: A continuous sampling was done during 20 days where the data was recorded every minute by using a sound level meter type I in a central axis of the intensive care unit for adults in the hospital; the recorded data corresponded to the maximum, minimum values and the equivalent continuous level of noise on frequency weighting A and the Fast time weighting filter. Results: It was reported that the equivalent continuous noise level varied between 49-71 dBA with a maximum value of 91, 19 dBA and a minimum of 46, 65 dBA. The variance analysis infers that the mean value of noise varies according to the time of day. Conclusions: The level of equivalent continuous noise presented in the intensive care unit for adults is consistent with other similar studies; however, the displayed values exceed the international standards of noise suggested, which generates a concern about the risks of exposure for the patients as well as for the medical staff of the unit.


Assuntos
Saúde Pública , Monitoramento do Ruído , Cuidados Críticos , Ruído Ocupacional
3.
rev. cuid. (Bucaramanga. 2010) ; 5(1): 595-605, ene.-dic. 2014. ilus, tab
Artigo em Espanhol | LILACS, BDENF | ID: lil-752174

RESUMO

Introducción: La evaluación de la calidad biológica del aire de ambientes hospitalarios resulta de especial interés debido a que los pacientes puedan servir como una fuente de bacterias patógenas para el personal del hospital, los visitantes y otros pacientes, siendo relevante en unidades de asistencia especializadas en atención de patologías crónicas como cáncer, SIDA y pacientes con trasplante de órganos o con complicaciones severas en su estado de salud, y que requieren una intervención masiva para su tratamiento en salas de cirugía y/o unidades de cuidado intensivo. Evaluar la influencia de factores ambientales y de ocupación de la unidad en la concentración de aerobacterias de unidades de cuidado intensivo del Hospital Universitario Fernando Troconis. Materiales y Métodos: Se colectaron muestras triplicadas con agar selectivo para Staphylococcus spp. y Pseudomonas spp., en dos estaciones de cada una de las tres UCI, mediante impactador de 2 etapas ubicado a altura de1.5m y caudal constante (28.3l/min) durante 5min, incubándolas a 37°C por 48h. Los factores ambientales se registraron con anemómetro Kestrel 4500 y ocupación de la unidad mediante registro manual del número de pacientes y personal asistencial de la unidad. Resultados: La máxima concentración fue 979.9±31.3UFC/m3 y el máximo promedio, 315.6±59.7UFC/m3. Staphylococcus spp. Superaron la concentración de Pseudomonas spp. La máxima ocupación fue en UCI Adulto, mayor temperatura en UCI Pediátrica y humedad más baja en UCI Adulto. Discusión y Conclusiones: La concentración de aerobacterias superó valores reportados por estudios aerobiológicos hospitalarios, y presenta relaciones leves con temperatura y escasa o nula con ocupación de la unidad.


Introduction: Assessing of biological quality of air in hospital environments is of particular interest because patients can be a source of pathogenic bacteria for hospital staff, visitors and other patients. It is relevant in specialized care of chronic diseases like cancer, AIDS and organ transplant patients or severe health complications, which require massive intervention for treatment in the operating room and/or intensive care units. To evaluate the influence of environmental factors and intensive care unit occupancy in the concentration of aerobacteria in intensive care units of Fernando Troconis Universitary Hospital. Materials and Methods: Triplicate samples were collected with selective agar for Staphylococcus spp. and Pseudomonas spp. using two-stage cascade impactor located 1.5 m high and constant flow (28.3l/min) for five minutes, locating two stations in each of the three ICU; the collected samples were incubated at 37°C for 48 hours. Environmental factors were recorded with anemometer Kestrel 4500 and occupancy of the unit by manually recording the number of patients and health care personnel of the unit. Results: Maximum concentration was 979.9±31.3CFU/m3 and maximum average 315.6±59.7CFU/m3. Staphylococcus spp. exceeded the concentration of Pseudomonas spp. Maximum intensive care unit occupancy was in adult ICU, higher temperature in pediatric ICU and lower humidity in adult ICU. Discussion and Conclusions: Aerobacteria concentration exceeded values reported by other aerobiological studies in hospital also has little relationship with temperature and little or no with intensive care unit occupancy.


Assuntos
Humanos , Meio Ambiente , Cuidados Críticos , Infecção Hospitalar , Ocupação de Leitos , Material Particulado , Viabilidade Microbiana